● RAIN, DUST & INSECTS PROTECTION The Rubber O-Ring & Rubber Grommets used in the SB-230/260DQ Series prevent rain, dust and tiny insects from adversely affecting performance. ● DOUBLE MODULATION IR BEAM FREQUENCY ● FORM C RELAY (N.C./N.O.) ● FROST & DEW PROTECTION An anti-frost design is to protect the detector from effect of frost & dew. ● 99% BEAM BLOCKING STABILITY Enabling stable operation with as mush as 99% loss of beam energy. The A.G.C. Circuit continually monitors for gradual changes in the signal's strength caused by weather conditions and adjusts the trigger level accordingly, to maintain proper sensitivity. ● AUTOMATIC GAIN CONTROL (A.G.C.) ● STAINLESS SCREWS & BACK PLATE ● ADJUSTABLE BEAM INTERRUPTION PERIOD Beam interruption time can be adjusted according to the peculiarities of each installation sits. When protecting a wall or fence, a long interruption time will catch intruders, but let jumping cats or small objects pass through. ● HEATING UNIT - HT-60 (OPTION PART) For use in cold areas ( Temperature control switch inside ), 24V DC/AC, 400mA max. (800mA/set) | |
---|---|
● SELECTABLE 4-CHANNEL BEAM FREQUENCY | |
1. 2-stacked protection. | 2.Line and 2-stacked protection. |
Model No | SB-230DQ | SB-260DQ | |
---|---|---|---|
Detection Distance | Outdoor | 100 ft. (30m) | 200 ft. (60m) |
Indoor | 200 ft. (60m) | 400 ft. (120m) | |
Max. Arrival Distance | 1000 ft.(300m) | 2000 ft.(600m) | |
Current Consumption | 67mA (max) | 85mA (max) | |
Selectable Beam Frequency | 4-channel | ||
Power Supply | 10.5V ~ 30VDC ( Non _Polarity ) | ||
Infrared Photoelectric | LED pulsed beam, Double modulation | ||
Detection System | Simultaneous breaking of 2 beams | ||
Response Time | 50msec ~ 700msec ( Adjustable ) | ||
Alarm Output | Dry connect relay NC./ NO. 0.2A / 28VDC Contact action: 1 To 3 sec . | ||
Tamper Output | Dry connect relay NC. 0.2A / 28VDC Action : cover is detached. | ||
Alarm LED | Red LED (Receiver) lights when an alarm is initiated. | ||
Attenuation LED | Yellow LED (Receiver) lights when beam is attenuated | ||
Functions | RF-Monitor Jack, Meter Monitor Jack output AGC circuit, Frost proof cover. | ||
Alignment Angle | Horizontal ±90°, Vertical ±5° | ||
Operating Temperature | -13°Fto +131°F( -25°C to +55°C) | ||
Mounting Positions | Indoor / Outdoor | ||
Wiring | Terminals | ||
Weight | 32.7oz(925g)Transmitter & Receiver | ||
Dimentions | W76 x H181.5 x D77.8 mm | ||
Standard Accessories | U-Shaped Brackets x 2 , Attenuation Sheet x 1 Screws ( 4x20 Self tapping ) x 4 , Screws ( M4 x 20 ) x 4 | ||
Option | Heating Unit (HT-60) |