Item. | PHC-50L | PHC-100L | PHC-150L | PHC-200L |
Detection Range | 10m | |||
---|---|---|---|---|
Power Supply | 10.5V~28VDC (12V is recommended) | |||
TX Current | A=18mA B=19mA C=22mA D=31mA | A=18mA B=19mA C=26mA D=42mA | A=18mA B=19mA C=29mA D=51mA | A=18mA B=19mA C=33mA D=60mA |
RX Current | 40mA | 46mA | 52mA | 58mA |
No. of beams | 2 dual 4 beams | 4 dual 8 beams | 6 dual 12 beams | 8 dual 16 beams |
Photoelectric | IR LED pulsed beam | |||
Detection | Breaking off 1 dual 2 beams or two adjacent | |||
Response Time | Breaking off 2 dual 4 beams (adjacent) : 50 msec. Breaking off 1 dual 2 beams : 100 msec. | |||
Alarm Output | Dry connect relay : NC./ NO. 0.2A / 28VDC (RX) Contact action: >2 sec. | |||
Tamper Output | Dry connect Micro-SW : NC. 0.2A / 28VDC Action : cover is detached.(TX & RX) | |||
LED | 1. Red LED ON: When an alarm is initiated ( RX ). 2. LED Flashing ( RX ):When receiver signal is weak. 3. Green LED ON: Power on ( TX ) | |||
Functions | 1. IR Power Set: 4 Level ( TX ) 2. Buzzer would sound when beam is blocked.( The sound function is optional. ) 3. Red LED with alignment checking purpose. 4. One dual with 2 beams. 5. With sunlight resistance. | |||
Temperature | -13℉ to +131℉ ( -25℃ to +55℃ ) | |||
Mounting | Indoor / Outdoor | |||
Wiring | Terminals | |||
Accessories | Screws ( Self tapping 4 x 25mm ) x 4. | |||
Option | Mounting Plate x4 (Screws(M4X16mm)x4 / Self tapping(4X20mm)x8 ). |