AQD-101
Air Quality Display
For PM2.5, CO2, Temperature and humidity measurements
AQD series displays four most crucial parameters of IAQ; CO2 level, PM2.5 concentration, humidity and temperature. It also provides date, day and time.
It uses good quality sensors; such as the NDIR CO2 sensor, laser scattering principle sensor for PM2.5, temperature and humidity sensors which are usually available only in laboratory air quality diagnostic equipment.
AQD-101 series measures CO2 and PM2.5 concentration which may not be noticeable by us and used the reading to control ventilation
so that the indoor CO2 level can be kept below the recommended ASHRAE limit of 1000ppm and it can ensure better indoor air quality.
Monitoring humidity is very important as extended period in an area with humidity over 60% or below 40% can create conditions for mold and mildew growth that may cause allergies and affect general health.




 
 
General
TypeWall mount
ParametersCO2, PM2.5, Relative Humidity, Temperature
Operating Environment-10 ~ 50 ℃ / 0 ~ 95%RH, non-condensing
Storage temperature-10~50 ℃
ClockReal time clock with battery backup
Power supply12 VDC (supply with an AC adapter 100~240V / 50~60Hz )
Current consumption1.2A (max)
Display7 segment LED display
StorageMicro
SD card 8G, 16G or 32G (Transcend, Adata and Kingston are recommended)
(not included in product kit)
Memory capacityDepending on SD card capacity
Storage formatCSV
CO2 Measurement
Measurement principleNon-dispersive infrared (NDIR) with automatic calibration
Measurement range0~9999 ppm
Accuracy tolerance0~2000ppm ± 3% and ± 40 ppm note1 and 2
Response time2 minutes by 90%
MaintenanceMaintenance-free for normal indoor applications
Display digit4 digits, 0 ~ 9999
Relay setting1200ppm
Hysteresis100ppm
PM2.5 Measurement
Measurement principleLaser distributing
Measurement range0 ~ 600 μg/m3
Accuracy tolerance0 ~ 100μg/m3 (±10 %μg/m3) , 100 ~ 600μg/m3 (±10%)
Response time≦10 s
MaintenanceMaintenance-free for normal indoor applications
Display digit3 digits , 0 ~ 999
Relay setting75 μg/m3
Hysteresis10 μg/m3
Humidity Measurement
Measurement range0 ~ 95 %RH
Accuracy tolerance± 3 %RH (typical)
Repeatability± 0.1 %RH
Response time τ63< 8 s (τ63%, 25℃)
Long-term drift< 0.5 %RH / year
Display digit2 digits, 0 ~ 99
Relay setting70%RH
Hysteresis5%RH
Temperature Measurement
Measurement range-10 ~ 50 ℃
Accuracy tolerance± 0.3 ℃ (typical)
Repeatability± 0.1 ℃
Response time5 ~ 30 s (τ63%, 25℃)
Long-term drift< 0.04 ℃ / year
Display digit3 digits (One decimal point), 0.0 ~ 99.9
Relay setting28℃
Hysteresis1℃
Outputs
RS-485RS485 (Modbus RTU)
LoRa (P2P)Radio frequency band: 868.0 ~ 912.9 MHz
Relay3 Relay outputs for CO2, relative humidity, and temperature respectively.
N.O. and N.C. (2A/30VDC)
Mechanical
Housing materialPMMA panel (4mm), SPCC casing (1mm)
Dimensions (mm)527(L) x 217(H) x 32(D)
Weight2700g
Note 1: In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation with ABC. However, some industrial
applications do require maintenance.℃
Note 2: Accuracy is specified at room temperature +25°C and at normal pressure 101.3 kPa. Specification is referenced to certified calibration
mixtures. Uncertainty of calibration gas mixtures (+-1% currently) is to be added to the specified accuracy for absolute measurements.